Diesel Fuel, 25 - 200 mg/m3, (8103475) DVP • Available for all threeDiesel Fuel, 25 200 mg m3, Part # 8103475, 10 Tests Application Range Standard Measuring Range: 25 to 200 mg m3 Number of Strokes n: 5 Time for Measurement: approx. 2. 5 min. Standard Deviation: Color Change: white brown Ambient Operating Conditions Temperature: 0 to 40 C Absolute Humidity: 40 mg H2O L Reaction Principle Undecane + I2O5 = I2 Cross Sensitivity Various organic compounds with changing sensitivity are displayed